Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
perf:knowl:mri:acq:b1 [2012/01/30 10:09]
jirik
perf:knowl:mri:acq:b1 [2012/01/30 10:10] (current)
jirik
Line 1: Line 1:
  
  
-Review in+Review in [1]:
  
 Although a number of methods have been proposed Although a number of methods have been proposed
Line 43: Line 43:
  
 References in [1]: References in [1]:
 +
 10. Insko E, Bolinger L. Mapping of the radio frequency field. J Magn Reson 10. Insko E, Bolinger L. Mapping of the radio frequency field. J Magn Reson
 Ser A 1993;​103:​82– 85. Ser A 1993;​103:​82– 85.
 +
 11. Stollberger R, Wach P. Imaging of the active B1 11. Stollberger R, Wach P. Imaging of the active B1
 field in vivo. Magn field in vivo. Magn
 Reson Med 1996;35:246 –251. Reson Med 1996;35:246 –251.
 +
 12. Sled JG, Pike GB. Correction for B1 12. Sled JG, Pike GB. Correction for B1
 and B0 and B0
 variations in quantitative T2 variations in quantitative T2
 measurements using MRI. Magn Reson Med 2000;43:589 –593. measurements using MRI. Magn Reson Med 2000;43:589 –593.
 +
 13. Fernandez-Seara MA, Song HK, Wehrli FW. Trabecular bone volume 13. Fernandez-Seara MA, Song HK, Wehrli FW. Trabecular bone volume
 fraction mapping by low-resolution MRI. Magn Reson Med 2001;46: fraction mapping by low-resolution MRI. Magn Reson Med 2001;46:
 103–113. 103–113.
 +
 14. Wang J, Qiu M, Constable RT. In vivo method for correcting transmit/ 14. Wang J, Qiu M, Constable RT. In vivo method for correcting transmit/
 receive nonuniformities with phased array coils. Magn Reson Med receive nonuniformities with phased array coils. Magn Reson Med
 2005;53:666 – 674. 2005;53:666 – 674.
 +
 15. Cunningham CH, Pauly JM, Nayak KS. Saturated double-angle method 15. Cunningham CH, Pauly JM, Nayak KS. Saturated double-angle method
 for rapid B1 mapping. Magn Reson Med 2006;​55:​1326 –1333. for rapid B1 mapping. Magn Reson Med 2006;​55:​1326 –1333.
 +
 16. Akoka S, Franconi F, Seguin F, Le Pape A. Radiofrequency map of an 16. Akoka S, Franconi F, Seguin F, Le Pape A. Radiofrequency map of an
 NMR coil by imaging. Magn Reson Imaging 1993;​11:​437– 41. NMR coil by imaging. Magn Reson Imaging 1993;​11:​437– 41.
 +
 17. Pan JW, Twieg DB, Hetherington HP. Quantitative spectroscopic imaging of the human brain. Magn Reson Med 1998;​40:​363–369. 17. Pan JW, Twieg DB, Hetherington HP. Quantitative spectroscopic imaging of the human brain. Magn Reson Med 1998;​40:​363–369.